Diagnostics
7.3 Diagnostics via data sets
M200D PROFIBUS/PROFINET
Manual, 08/2014, A5E01577426A/RS-AA/004
149
Statistical data (DS 95)
The following data is stored in data set 95 (Page 206) of the starter:
Operating hours device
Operating hours motor
Operating hours motor current= 18 to 49.9% of I
e
max
Operating hours motor current= 50 to 89.9 % of I
e
max
Operating hours motor current= 90 to 119.9 % of I
e
max
Operating hours motor current= 120 to 1000 % of I
e
max
Number of starts motor CW
Number of starts motor CCW (RSte/sRSSte only)
Number of motor overload trips
Number of switching element overload trips
Number of starts output 1
Number of starts output 2
Number of stops with mechanical braking
1)
Number of short-circuit trips
Last tripping current I
A
(%)
Last tripping current I
A
(eff)
Motor current I
max
(%)
Motor current I
max
(rms)
Number of starts output BO
1)
Maintenance timer
1)
For all motor starters with brake output
On M200D PROFIBUS/PROFINET motor starters, the operating hours are saved in the
event of power failure (a maximum of 6 minutes can be lost). Statistical data can be read out
via "Motor Starter ES" or the PLC with SFC59 or SFB 53.