EasyManuals Logo

STMicroelectronics STM32F407 User Manual

STMicroelectronics STM32F407
1731 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #1070 background imageLoading...
Page #1070 background image
Controller area network (bxCAN) RM0090
1070/1731 DocID018909 Rev 11
32.3.2 Control, status and configuration registers
The application uses these registers to:
Configure CAN parameters, e.g. baud rate
Request transmissions
Handle receptions
Manage interrupts
Get diagnostic information
32.3.3 Tx mailboxes
Three transmit mailboxes are provided to the software for setting up messages. The
transmission Scheduler decides which mailbox has to be transmitted first.
32.3.4 Acceptance filters
The bxCAN provides 28 scalable/configurable identifier filter banks for selecting the
incoming messages the software needs and discarding the others.
Receive FIFO
Two receive FIFOs are used by hardware to store the incoming messages. Three complete
messages can be stored in each FIFO. The FIFOs are managed completely by hardware.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STMicroelectronics STM32F407 and is the answer not in the manual?

STMicroelectronics STM32F407 Specifications

General IconGeneral
BrandSTMicroelectronics
ModelSTM32F407
CategoryController
LanguageEnglish

Related product manuals