EasyManuals Logo

STMicroelectronics STM32F407 User Manual

STMicroelectronics STM32F407
1731 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #217 background imageLoading...
Page #217 background image
DocID018909 Rev 11 217/1731
RM0090 Reset and clock control for STM32F405xx/07xx and STM32F415xx/17xx(RCC)
268
The clock controller provides a high degree of flexibility to the application in the choice of the
external crystal or the oscillator to run the core and peripherals at the highest frequency
and, guarantee the appropriate frequency for peripherals that need a specific clock like
Ethernet, USB OTG FS and HS, I2S and SDIO.
Several prescalers are used to configure the AHB frequency, the high-speed APB (APB2)
and the low-speed APB (APB1) domains. The maximum frequency of the AHB domain is
168 MHz. The maximum allowed frequency of the high-speed APB2 domain is 84 MHz. The
maximum allowed frequency of the low-speed APB1 domain is 42 MHz
All peripheral clocks are derived from the system clock (SYSCLK) except for:
The USB OTG FS clock (48 MHz), the random analog generator (RNG) clock
( 48 MHz) and the SDIO clock ( 48 MHz) which are coming from a specific output of
PLL (PLL48CLK)
The I2S clock
To achieve high-quality audio performance, the I2S clock can be derived either from a
specific PLL (PLLI2S) or from an external clock mapped on the I2S_CKIN pin. For
more information about I2S clock frequency and precision, refer to Section 28.4.4:
Clock generator.
The USB OTG HS (60 MHz) clock which is provided from the external PHY
The Ethernet MAC clocks (TX, RX and RMII) which are provided from the external
PHY. For further information on the Ethernet configuration, please refer to
Section 33.4.4: MII/RMII selection in the Ethernet peripheral description. When the
Ethernet is used, the AHB clock frequency must be at least 25 MHz.
The RCC feeds the external clock of the Cortex System Timer (SysTick) with the AHB clock
(HCLK) divided by 8. The SysTick can work either with this clock or with the Cortex clock
(HCLK), configurable in the SysTick control and status register.
The timer clock frequencies are automatically set by hardware. There are two cases:
1. If the APB prescaler is 1, the timer clock frequencies are set to the same frequency as
that of the APB domain to which the timers are connected.
2. Otherwise, they are set to twice (×2) the frequency of the APB domain to which the
timers are connected.
FCLK acts as Cortex
®
-M4 with FPU free-running clock. For more details, refer to the
Cortex
®
-M4 with FPU technical reference manual.
7.2.1 HSE clock
The high speed external clock signal (HSE) can be generated from two possible clock
sources:
HSE external crystal/ceramic resonator
HSE external user clock
The resonator and the load capacitors have to be placed as close as possible to the
oscillator pins in order to minimize output distortion and startup stabilization time. The
loading capacitance values must be adjusted according to the selected oscillator.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the STMicroelectronics STM32F407 and is the answer not in the manual?

STMicroelectronics STM32F407 Specifications

General IconGeneral
BrandSTMicroelectronics
ModelSTM32F407
CategoryController
LanguageEnglish

Related product manuals