Blue LED Behavior Description
Off Remote maintenance not active
Single flash Connection established to the teleserver
Flashing Drive controller waits for connection to DriveControlSuite
On Remote maintenance is active
Tab. 146: Meaning of the blue LED (REMOTE)
LEDs:
Green/Red
Behavior Description
Off No supply voltage
Off
Single flash STO active
Off
Flashing Ready to switch on
Off
On Normal operation
Off
Rapid flashing Data is written to internal memory and the SD card
Off
On Warning in the 4: Enabled device state
Flashing
Flashing Warning in the 2: Ready for switch-on device state
Flashing
Off Fault
On
Off No configuration active
Rapid flashing
Tab. 147: Meaning of the green and red LED (RUN)