5 | Technical data STOBER
32
12/2018 | ID 442537.05
Operating conditions
Surrounding temperature during
operation
0°C to 45°C with nominal data
45°C to 55°C with derating −2.5%/K
Relative humidity Maximum relative humidity 85%, non-condensing
Installation altitude 0m to 1000m above sea level without restrictions
1000m to 2000m above sea level with −1.5%/100m derating
Pollution degree Pollution degree 2 in accordance with EN 50178
Vibration (operation) in accordance
with DIN EN 60068-2-6
5Hz ≤ f ≤ 9Hz: 0.35mm
9Hz ≤ f ≤ 200Hz: 1m/s²
Tab. 35: Operating conditions
5.2.2 DL6A – SD6 assignment
DL6A is available in the following designs, appropriate for the sizes of the drive controller:
Type DL6A0 DL6A1 DL6A2 DL6A3
ID No. 56440 56441 56442 56443
SD6A02 X — — —
SD6A04 X — — —
SD6A06 X — — —
SD6A14 — X — —
SD6A16 — X — —
SD6A24 — — X —
SD6A26 — — X —
SD6A34 — — — X
SD6A36 — — — X
SD6A38 — — — X
Tab. 36: Assignment of DL6A to SD6