OPTIONS & ALLIED TOOLING − DECO 7/10 − DECO 7a/10a − DECO 7e/10e
300236 en − 02/07 Chap. 21.2 /7
PMC PRM (TIMER)
#001
MONIT (RUN / STOP)
NO ADDRESS DATA NO ADRESS DATA
01 T00 600000 11 T20 96
02 T02 300000 (time pump OFF in ms: 300 sec. =
5 min.)
03 T04 60000 (time pump ON in ms: 60 sec. = 1
min.)
04 T06 1488
09 T16 1000 19 T36 0
10 T18 800 20 T38 0
Get positioned on line 02 T02 30
0000, type on NC keyboard the time of disengagement (OFF) of the
pump and press INPUT key.
Get positioned on line 03 T04 60
000, type on NC keyboard the time of engagement (ON) of the pump
and press INPUT key.
>>>