InstallinganAdjustableFitting(continued)
7.Holdthettinginthecorrectalignmentwithawrenchanduseatorque
wrenchandtightenthettingtotherecommendedtorquevaluewithinthe
speciedrangeoftorquevalues;refertotheFittingInstallationT orqueT able
(page5–12).Thistighteningprocedurerequiresadrive-adapterwrench
(e.g.,crowfootwrench).
Note:Itmaybenecessarytouseadrive-adapterwrench(e.g.,crowfoot
wrench)toinstallahydraulictting;refertoCalculatingtheT orqueValues
WhenUsingaDrive-AdapterWrench(page2–7).
8.Ifatorquewrenchisnotavailableorifspaceattheportpreventstheuse
ofatorquewrench,usethealternativeprocedureFlatFromFingerTight
Table(page5–14)givenbelow;
A.Holdthettinginthecorrectalignmentwithawrenchand,iftheport
materialissteel,tightenthelocknutwithasecondwrenchtothelisted
FFFT(Step4inFigure41).
B.Iftheportmaterialisaluminum,tightenthettingto60%ofthelisted
FFFT;refertotheFlatFromFingerTightT able(page5–14).
FlatFromFingerTightTable
Size
FFFT
4(1/4inchnominalhoseortubing)
1.00±0.25
6(3/8inch)
1.50±0.25
8(1/2inch)
1.50±0.25
10(5/8inch)
1.50±0.25
12(3/4inch)
1.50±0.25
16(1inch)
1.50±0.25
HydraulicSystem:GeneralInformation
Page5–14
Groundsmaster
®
3280-D/3320
05138SLRevB