8
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
ERROR CODE and TROUBLESHOOTING
8 - 299
8.5.4 Poor image density, color reproduction and gray balance
Fig.8-12
Cause/Section Step Check item Measures Remarks
Density / Color
reproduction /
Gray balance
1 Check the image density / color
reproduction / gray balance.
Perform the enforced
performing of image quality
closed-loop control (05-2742)
and then automatic gamma
adjustment.
Printer density 2 Check the density of printer
output image.
Output the test patterns and
check them.
Color: using 04-231 for each
color
Black: using 04-113
Laser array breakage detection
pattern: print it out at the code
04-286.
See step
5 if defect
occurs.
Scanner 3 Check if the original glass,
mirrors or lens is dirty.
Clean it.
Parameter
adjustment
value
4 Check the image processing
parameters.
Adjust the color balance (color).
Adjust the image density.
Check color reproduction. Check color reproduction.
Check image density.Check gray balance.

Table of Contents

Other manuals for Toshiba e-studio 6560c

Related product manuals