DISASSEMBLY and REPLACEMENT
4 - 80
4.5.50 Tandem LCF end fence motor (M47)
(7) Release 4 latches and then take off the
tandem LCF tray-up motor.
Fig. 4-233
(1) Pull out the tandem LCF.
(2) Take off the FIL board case and reactor.
P. 9-21"9.1.18 FIL board"
(3) Take off the switching regulator.
P. 9-18"9.1.15 Switching regulator (PS)"
(4) Take off the PFC board case.
P. 9-8"9.1.9 PFC board case"
(5) Disconnect 1 connector and remove 3
screws. Then take off the tandem LCF end
fence motor unit [1].
Notes:
Do not mix the tandem LCF tray-up motor
and the tandem LCF end fence motor [1]
when installing them.
Fig. 4-234
(6) Release 2 latches and then take off the
coupling and spring.
Fig. 4-235
Cover
Tandem LCF
tray-up motor
[
1
]
Spring
Coupling