ERROR CODE and TROUBLESHOOTING
8 - 131
8.3.17 RADF related service call
[C730] EEPROM abnormality
[C880] RADF original feed motor abnormality
[C890] RADF read motor abnormality
Classification Error item
Optional communication related
service call
Data abnormality occurs during the EEPROM writing of the
RADF is performed.
Check item Measures
RADF board Connector check
Harness check
Board check IC12)
Replace parts Remarks
RADF board Replace the RADF board, and then perform the automatic
adjustment for the original reading start sensor (05-3210).
Classification Error item
Optional communication related
service call
An error signal has been detected when the motor is rotating.
Check item Measures
RADF board Connector check (CN76)
Harness check
Board check
RADF original feed motor (MR1) Motor check
(Perform the output check: 03-281)
Connector check
Harness check
Replace parts Remarks
RADF original feed motor
RADF board Replace the RADF board, and then perform the automatic
adjustment for the original reading start sensor (05-3210).
Classification Error item
Optional communication related
service call
An error signal has been detected when the motor is rotating.
Check item Measures
RADF board Connector check (CN76)
Harness check
Board check
RADF read motor (MR2) Motor check
(Perform the output check: 03-283)
Connector check
Harness check