4
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT
4 - 197
4.9.16 IH coil
(9) Remove 2 screws each and take off the
pressure roller center thermostat and the
pressure roller side thermostat from each
bracket.
Notes:
• Do not touch the temperature detection
section of the pressure roller thermostat.
• When replacing the pressure roller center
thermostat or the pressure roller side one,
check the gap between this and the
pressure roller. P. 6-103"6.11.3 Gap
adjustment for pressure roller
thermostats"
• Install the correct pressure roller
thermostat since the center and side ones
are similar but different.
Fig. 4-570
Fig. 4-571
(1) Take off the fuser unit.
P. 4-172"4.9.1 Fuser unit"
(2) Open the SYS board case.
P. 9-2"9.1.3 SYS board case"
(3) Release a harness from the clamp and
disconnect 2 connectors.
(4) Remove 4 screws and take off the IH board
cover.
Fig. 4-572
Pressure roller
center thermostat
Pressure roller
side thermostat
Pressure roller
center thermostat
Pressure roller
side thermostat