e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY and REPLACEMENT
4 - 238
4.10.33 Duplexing bridge unit
4.10.34 Duplexing unit opening/closing detection sensor (S64)
(1) Take off the right top cover.
P. 4-2"4.1.4 Right top cover"
(2) Take off the fuser unit.
P. 4-172"4.9.1 Fuser unit"
(3) Remove 1 screw and take off the cover.
Fig. 4-691
(4) Remove 2 screws and disconnect 1
connector. Then take off the duplexing bridge
unit.
Fig. 4-692
(1) Take off the duplexing bridge unit.
P. 4-238"4.10.33 Duplexing bridge unit"
(2) Remove 2 E-rings, 2 pulleys and 1 belt.
Fig. 4-693