4
© 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C
DISASSEMBLY and REPLACEMENT
4 - 239
4.10.35 Reverse path sensor (S57)
(3) Take off the duplexing unit opening/closing
detection sensor from its frame.
(4) Disconnect a connector from the duplexing
unit opening/closing detection sensor [1].
Notes:
When installing the sensor, be careful not to
bend the latches of the sensor.
Fig. 4-694
(1) Take off the duplexing bridge unit.
P. 4-238"4.10.33 Duplexing bridge unit"
(2) Remove 1 screw and then take off the
sensor bracket.
(3) Release a harness from a clamp and then
disconnect a connector from the sensor
bracket.
Fig. 4-695
(4) Remove 1 E-ring and a pin. Then remove the
sensor actuator.
Notes:
When installing the sensor, hook the spring
securely and make sure that the actuator
returned to its original position by the spring
force.
Fig. 4-696
[
1
]
Sensor bracket