e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY and REPLACEMENT
4 - 100
4.6.9 Needle electrode
4.6.10 Discharge LED (ERS-K/ERS-C/ERS-M/ERS-Y)
4.6.11 Sub-hopper
(1) Take off the needle electrode cleaner.
P. 4-99"4.6.8 Needle electrode cleaner"
(2) Remove the holder and then take off the
needle electrode.
Fig. 4-291
(1) Take off the main charger unit.
P. 4-99"4.6.6 Main charger unit"
(2) Remove the discharge LED from the
protrusion of the charger case and take it off
by sliding it.
Fig. 4-292
(1) Pull out the process unit.
P. 4-91"4.6.1 Pulling out the process unit
(EPU tray)"
(2) Disconnect 4 connectors.
(3) Release 4 hooks on the both sides.
(4) Release 4 hooks on the front and back side.
(5) Release the harness from 2 hooks, and take
out the sub-hopper [1].
Fig. 4-293