e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
DISASSEMBLY and REPLACEMENT
4 - 20
4.3.6 Exposure lamp cooling fan-1 (F2)
(1) Open the RADF.
(2) Take off the original glass.
P. 4-15"4.3.1 Original glass"
(3) Move the carriage-1 to the right side.
Fig. 4-54
Notes:
Rotate the drive pulley to move the carriage.
Fig. 4-55
(4) Disconnect 1 connector.
(5) Remove 3 screws, and take off the Exposure
lamp cooling fan-1.
Notes:
When installing the fan, do not tighten the
screw too much.
Fig. 4-56
Drive pulley
Exposure lamp cooling fan-1