FIRMWARE UPDATING
11 - 15
• If the USB device are not recognized properly, “USB device Not detected” is displayed. In this
case, disconnect the USB device and connect it again within 3 minutes, or shut down the
equipment and connect the device properly. Then repeat the procedure from (4).
• If any of the error messages below is displayed, confirm if the update program or the data file
in the USB device is correct. Then repeat the procedure from (4)
(6) Select the item with the digital keys.
“*” is displayed next to the selected item. Display or delete the “*” by pressing the number of the
item.
Notes:
The display of items on this screen varies depending on the updating method.
(7) Press the [START] button.
Updating starts and the processing status is displayed on the LCD screen.
Notes:
The display of items on this screen varies depending on the updating method.
Error
number
Error message Cause
01 Error Loadmodule Module loading failed.
02 Machine Model Get Error Module information downloading
failed.
03 Copy Data with valid signature in USB
Storage
Data file check failed.
04 Other models ROMDATA TXXXXXXXX
* The version name comes at
“xxxx.xxx.x”.
Master data of other model are
stored.
05 Copy Signature File in USB Storage Data files are not stored in a USB
device.
06 Patch and Normal package in one folder of
USB Storage
When both the system and patch
update packages are in a USB
device together.
Item Remarks
1. SYSTEM FIRMWARE(OS Data) Updating OS data
2. ENGINE FIRMWARE Updating Engine ROM
3. SCANNER FIRMWARE Updating Scanner ROM
4. S
YSTEM SOFTWARE (HD Data)
Updating Master data (HDD program data)
5. RADF FIRMWARE Updating RADF ROM
6. PFC FIRMWARE Updating PFC ROM
Status display during the update Status display when the update is completed
SYSTEM FIRMWARE (OS Data) update in
progress
SYSTEM FIRMWARE (OS Data)
Completed
ENGINE FIRMWARE update in progress ENGINE FIRMWARE Completed
SCANNER FIRMWARE update in progress CANNER FIRMWARE Completed
SYSTEM SOFTWARE (HD Data) update in
progress
SYSTEM SOFTWARE (HD Data) Completed
RADF FIRMWARE update in progress RADF FIRMWARE Completed
PFC FIRMWARE update in progress PFC FIRMWARE Completed