Loading...
e-STUDIO5540C/6540C/6550C
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
05
Inspection of the sensors
around the process unit
Displays the controlling status of the drum surface
potential (V0) sensor and the drum surface
potential (V0) sensor shutter closing in each of Y,
M, C and K when [ERROR] occurs.
Upper row:
Drum surface potential (V0) sensor
Lower row:
Drum surface potential (V0) sensor shutter closing
0: Normally finished
1: Control paused
2: Sensor / shutter closing abnormality
Adjustment
mode
Process
Image quality
control
2788
6
M
05
Sensor shutter-Y
Displays the controlling status of the drum surface
potential sensor shutter closing with a digit as
follows:
0: Normally finished1: Control paused2: Sensor
abnormality
Adjustment
mode
Process
Image quality
control
Drum surface
potential sensor
shutter closing
controlling status
2789
0
0
0~2
10
M
05
Sensor shutter-M
Displays the controlling status of the drum surface
potential sensor shutter closing with a digit as
follows:
0: Normally finished1: Control paused2: Sensor
abnormality
Adjustment
mode
Process
Image quality
control
Drum surface
potential sensor
shutter closing
controlling status
2789
1
0
0~2
10
M
05
Sensor shutter-C
Displays the controlling status of the drum surface
potential sensor shutter closing with a digit as
follows:
0: Normally finished1: Control paused2: Sensor
abnormality
Adjustment
mode
Process
Image quality
control
Drum surface
potential sensor
shutter closing
controlling status
2789
2
0
0~2
10
M
05
Sensor shutter-K
Displays the controlling status of the drum surface
potential sensor shutter closing with a digit as
follows:
0: Normally finished1: Control paused2: Sensor
abnormality
Adjustment
mode
Process
Image quality
control
Drum surface
potential sensor
shutter closing
controlling status
2789
3
0
0~2
10
M
05
Y color (low gradation 1)
TRC control pattern
Detection values for low gradation 1, low gradation
2, low gradation 3 of each color
Adjustment
mode
Process
Image quality
control
TRC control
pattern detection
value
2800
0
0
0~1023
10
M
05
Y color (low gradation 2)
TRC control pattern
Detection values for low gradation 1, low gradation
2, low gradation 3 of each color
Adjustment
mode
Process
Image quality
control
TRC control
pattern detection
value
2800
1
0
0~1023
10
M
05
Y color (low gradation 3)
TRC control pattern
Detection values for low gradation 1, low gradation
2, low gradation 3 of each color
Adjustment
mode
Process
Image quality
control
TRC control
pattern detection
value
2800
2
0
0~1023
10
M
05
M color (low gradation 1)
TRC control pattern
Detection values for low gradation 1, low gradation
2, low gradation 3 of each color
Adjustment
mode
Process
Image quality
control
TRC control
pattern detection
value
2800
3
0
0~1023
10
M
05
M color (low gradation 2)
TRC control pattern
Detection values for low gradation 1, low gradation
2, low gradation 3 of each color
Adjustment
mode
Process
Image quality
control
TRC control
pattern detection
value
2800
4
0
0~1023
10
M
05
M color (low gradation 3)
TRC control pattern
Detection values for low gradation 1, low gradation
2, low gradation 3 of each color
Adjustment
mode
Process
Image quality
control
TRC control
pattern detection
value
2800
5
0
0~1023
10
M
05
C color (low gradation 1)
TRC control pattern
Detection values for low gradation 1, low gradation
2, low gradation 3 of each color
Adjustment
mode
Process
Image quality
control
TRC control
pattern detection
value
2800
6
0
0~1023
10
M
6