e-STUDIO5540C/6540C/6550C
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
08
Heat roller: special paper 1,
long size paper
0: Invalid
1 to 10: Setting value * 1 (sec.)
Setting
mode
Process
Fuser
Special paper:
Heater forced On
time
2016
4
0
0~10
4
M
08
Heat roller: special paper 2,
long size paper
0: Invalid
1 to 10: Setting value * 1 (sec.)
Setting
mode
Process
Fuser
Special paper:
Heater forced On
time
2016
5
0
0~10
4
M
08
Press roller: special paper
1, long size paper
0: Invalid
1 to 10: Setting value * 1 (sec.)
Setting
mode
Process
Fuser
Special paper:
Heater forced On
time
2016
6
5
0~10
4
M
08
Press roller: special paper
2, long size paper
0: Invalid
1 to 10: Setting value * 1 (sec.)
Setting
mode
Process
Fuser
Special paper:
Heater forced On
time
2016
7
5
0~10
4
M
08
Special paper 1 / Normal
length paper
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: 180ºC 13: 185ºC 14:
190ºC 15: 195ºC 16: 200ºC
Setting
mode
Process
Fuser
Fusing
temperature
(Center / Fuser
belt / Special
paper)
2017
0
11
0~16
4
M
08
Special paper 2 / Normal
length paper
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: 180ºC 13: 185ºC 14:
190ºC 15: 195ºC 16: 200ºC
Setting
mode
Process
Fuser
Fusing
temperature
(Center / Fuser
belt / Special
paper)
2017
1
11
0~16
4
M
08
Special paper 1 / Extra long
size paper
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: 180ºC 13: 185ºC 14:
190ºC 15: 195ºC 16: 200ºC
Setting
mode
Process
Fuser
Fusing
temperature
(Center / Fuser
belt / Special
paper)
2017
2
11
0~16
4
M
08
Special paper 2 / Extra long
size paper
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: 180ºC 13: 185ºC 14:
190ºC 15: 195ºC 16: 200ºC
Setting
mode
Process
Fuser
Fusing
temperature
(Center / Fuser
belt / Special
paper)
2017
3
11
0~16
4
M
08
Special paper 1 / Normal
length paper
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: 180ºC 13: 185ºC 14:
190ºC 15: 195ºC 16: 200ºC
Setting
mode
Process
Fuser
Fusing
temperature
(Center /
Pressure roller /
Special paper)
2019
0
4
0~16
4
M
08
Special paper 2 / Normal
length paper
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: 180ºC 13: 185ºC 14:
190ºC 15: 195ºC 16: 200ºC
Setting
mode
Process
Fuser
Fusing
temperature
(Center /
Pressure roller /
Special paper)
2019
1
4
0~16
4
M
08
Special paper 1 / Extra long
size paper
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: 180ºC 13: 185ºC 14:
190ºC 15: 195ºC 16: 200ºC
Setting
mode
Process
Fuser
Fusing
temperature
(Center /
Pressure roller /
Special paper)
2019
2
4
0~16
4
M
08
Special paper 2 / Extra long
size paper
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: 180ºC 13: 185ºC 14:
190ºC 15: 195ºC 16: 200ºC
Setting
mode
Process
Fuser
Fusing
temperature
(Center /
Pressure roller /
Special paper)
2019
3
4
0~16
4
M
3