e-STUDIO5540C/6540C/6550C
05/08
Mode
Element
Sub Element
Item
Subitem
Code
Sub-
Code
Details
Default
value
Acceptable
value
RAM
Contents
Proc
edure
ServiceUI
08
Manual mode: Plain paper1
(one-side printing)
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: Invalid
Setting
mode
Process
Fuser
Plain paper:
Temperature
setting to start
error handling
(normal
temperature
environment)
Center and side
thermistor
2080
0
7
0~12
4
M
08
Manual mode: Plain paper 2
(one-side printing)
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: Invalid
Setting
mode
Process
Fuser
Plain paper:
Temperature
setting to start
error handling
(normal
temperature
environment)
Center and side
thermistor
2080
1
8
0~12
4
M
08
Auto mode: Plain paper 1
(one-side printing)
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: Invalid
Setting
mode
Process
Fuser
Plain paper:
Temperature
setting to start
error handling
(normal
temperature
environment)
Center and side
thermistor
2080
2
7
0~12
4
M
08
Auto mode: Plain paper 2
(one-side printing)
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: Invalid
Setting
mode
Process
Fuser
Plain paper:
Temperature
setting to start
error handling
(normal
temperature
environment)
Center and side
thermistor
2080
3
8
0~12
4
M
08
Bypass feed (one-side
printing)
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: Invalid
Setting
mode
Process
Fuser
Plain paper:
Temperature
setting to start
error handling
(normal
temperature
environment)
Center and side
thermistor
2080
4
7
0~12
4
M
08
Manual mode: Plain paper 1
(duplex printing)
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: Invalid
Setting
mode
Process
Fuser
Plain paper:
Temperature
setting to start
error handling
(normal
temperature
environment)
Center and side
thermistor
2080
5
6
0~12
4
M
08
Manual mode: Plain paper 2
(duplex printing)
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: Invalid
Setting
mode
Process
Fuser
Plain paper:
Temperature
setting to start
error handling
(normal
temperature
environment)
Center and side
thermistor
2080
6
7
0~12
4
M
08
Auto mode: Plain paper 1
(duplex printing)
0: 120ºC 1: 125ºC 2: 130ºC 3: 135ºC 4: 140ºC
5: 145ºC 6: 150ºC 7: 155ºC 8: 160ºC 9: 165ºC
10: 170ºC 11: 175ºC 12: Invalid
Setting
mode
Process
Fuser
Plain paper:
Temperature
setting to start
error handling
(normal
temperature
environment)
Center and side
thermistor
2080
7
6
0~12
4
M
7
Ver11