e-STUDIO5540C/6540C/6550C/5560C/6560C/6570C © 2011 - 2015 TOSHIBA TEC CORPORATION All rights reserved
SETTING ADJUSTMENT
6 - 128
(7) Perform the automatic adjustment (05-3210).
Notes:
After the manual adjustment is performed, be sure to do the automatic one.
(8) Turn the power OFF and install the cover.
Notes:
If LED 3 does not light, follow the procedure
below.
1. Tighten 2 prism vertical fixing screws
aligning with the forth mark-off line from
the top.
2. Loosen the 2 prism horizontal adjustment
screws.
3. Slide the prism horizontally. When the
prism comes to the proper adjustment
position, LED 3 on the RADF board lights.
At this position, tighten 2 prism horizontal
adjustment screws.
Fig.6-122
Fig.6-123
Fig.6-124