ERROR CODE and TROUBLESHOOTING
8 - 171
[CE50] Temperature/humidity sensor abnormality
[CE60] Drum thermistor-Y abnormality
[CE90] Drum thermistor-K abnormality
Check item Measures
Image quality sensor (S23) Sensor check
Connector check
Harness check
IMG board Connector check (CN422)
Harness check
SYS board Connector check (CN116, CN132, CN135)
Harness check
HDD Format the HDD. ([5] + [C] + [POWER] ON -> [3] -> [2])
Connector check
Harness check
Replace parts Remarks
HDD
SYS board
Classification Error item
Image control related service call The output value of this sensor is out of a specified range.
Check item Measures
Temperature/humidity sensor (S12) Sensor check
(Perform the input check: 03-[ALL]OFF/[1], 03-[ALL]OFF/
[2])
Connector check
Harness check
LGC board Connector check (CN310)
Harness check
Replace parts Remarks
Temperature/humidity sensor
LGC board
Classification Error item
Copy process related service call The output value of the drum thermistor-Y is out of a specified
range. (CE60)
The output value of the drum thermistor-K is out of a specified
range. (CE90)
Check item Measures
EPU tray (process unit) Connection check (05-2788)
Connector check(CN551, CN553, CN556)
Harness check