• Hail accumulation limit.
Make the desir
ed setting with the following command. Select the correct value/letter for the
setting fields.
C
ommand format in ASCII and NMEA 0183:
aRU,R=x,I=x, U=x,S=x,M=x,Z=x, X=x, Y=x<cr><lf>
Command f
ormat in SDI-12:
aXRU,R=x,I=x,U=x,S=x,M=x,Z=x, X=x,Y=x!
R, I, U, S, M, Z,
X, Y
Precipitation sensor setting fields.
x
Input value for the setting
<cr><lf>
Command terminator in ASCII and NMEA 0183
!
Command terminator in SDI-12
Examples (ASCII and NMEA 0183):
Changing the precipita
tion units to imperial:
0RU,U=I<cr><lf>
0RU,U=I<cr><lf>
Changing the auto-send mode t
o the tipping bucket mode:
0RU,M=C<cr><lf>
0RU,M=C<cr><lf>
Making the Rain amount
Rc and Rain intensity Ri available both in the precipitation
message and composite data message:
0RU,R=1010000010100000<cr><lf>
0RU,R=10100000&10100000<cr><lf>
The r
esponse after the change:
Chapter 8 – Sensor and Data Message Settings
131