EN50131 Requirement (and relevant section) Relevant Vanderbilt documentation
Programmable functions provided Engineer programming via the keypad on
page112
Engineer programming via the browser on
page172
How indications are made inaccessible to level 1 users when
level 2, 3 or 4 user is no longer accessing the information (see
8.5.1)
Keypad user interface on page93
LCD Keypad Settings on page126
Comfort Keypad Settings on page127
Configuring an Indicator Expander on page240
Masking/reduction of range signals/messages processed as
“fault” or “masking” events (see 8.4.1, 8.5.1 and Table 11)
System Options on page252
Wiring the zone inputs on page85
SIA Codes on page368
PIR masking is always reported as a zone
masked event (SIA - ZM). Additionally, anti-
mask can cause an alarm, tamper, trouble or no
additional action depending on configuration
Current defaults of PIR addition effect:
Ireland
Unset - None
Set - Alarm
UK, Europe, Sweden, Swiss, Belgium
Unset - Tamper
Set - Alarm
Prioritization of signal and message processing and indications
(see 8.4.1.2, 8.5.3)
Using the LCD keypad interface on page95
Using the Comfort keypad interface - see About
the Comfort keypad on page99
Minimum number of variations of PIN codes, logical keys,
biometric keys and/or mechanical keys for each user (see 8.3)
User PIN combinations on page376
Method of time-limiting internal WD for level 3 access without
level 2 authorization (see 8.3.1)
Not supported - Engineer cannot access system
without permission.
Number and details of disallowed PIN codes (see 8.3.2.2.1) Automatic inhibits on page376
Details of any biometric authorization methods used (see
8.3.2.2.3)
Not applicable
Method used to determine the number of combinations of PIN
codes, logical keys, biometric keys and/or mechanical keys
(see 11.6)
User PIN combinations on page376
Number of invalid code entries before user interface is disabled
(see 8.3.2.4)
Access PINs on page377
Details of means for temporary authorization for user access
(see 8.3.2)