14.1 Drives
14 -7
Model CIMR-MR5j
*
2
25P5 27P5 2011 2015 2018 2022 2030
Required Power Capacity (kVA) 9 12 19 24 30 36 48
Continuous Rated Input Current
(A)
13.3 19.7 26.8 39.3 53.6 66.1 78.6
Continuous Rated Output Current
(A)
17.6 26.2 35.7 52.4 71.4 88.1 104.8
Power Supply
Three-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to 15%, allowable frequency fluctuation: ±5%,
Line-to-line voltage unbalance: 5% or less)
C
onverter
*
4
Control Power Supply
Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to 15%, allowable frequency fluctuation: ±5%)
Required power capacity: 100 VA (for independent drive system)
250 VA (for NC system)
C
o
Control Method
Power regenerative control (120_ current conduction)
Overload Capacity 120% for one minute, 200% for one second
o
ller
Approx. Mass lb (kg) 11 (5) 27 (12) 35 (16)
o
ntro
Di i
i
ih
Width 3.94 (100) 5.91 (150) 7.84 (200)
Co
n
Dimensions in inches
(mm)
*3
Height 13.78 (350)
(
mm
)
*
3
Depth 12.60 (320)
Power Supply AC Reactor Code
No.
X010058 X010059 X010060 X010061 X010062 X010063 X010064
Model CIMR-M5j
*2
CIMR-MR5j
*2
25P5 27P5 2011 2015 2018 2022 2030
Ambient Temperature
0°Cto55°C (32°F to 131°F) (not frozen)
n
Heatsink Intake Air Temperature
0°Cto45°C (32°Fto113°F)
mon
Storage Temperature
*5
20°Cto60°C(4°F to 140°F)
C
om
m
Humidity 90% or less (non-condensing)
C
o
Location Indoor (protected from corrosive gases and dust), elevation: 1000 m (3280 ft) or less
Vibration 9.8 m/s
2
(1G) at 10 to less than 20 Hz, up to 2 m / s
2
(0.2G) at 20 to 50 Hz
Protective Structure
IEC IP00
(Protected so that parts of the human body cannot reach electrically charged parts from the front)
* 1. Rated output power is guaranteed when input voltage is three-phase, 200 V (50/60 Hz), 220 V (50/60 Hz), 230 V (60 Hz). If
input voltage is lower than 200 V, rated output power is not guaranteed.
* 2. A: For stand-alone drive system N: for NC system
* 3. Dimensions of External Heatsink Cooling Type. Refer to 14.1.3 Dimensions for Open Chassis Type.
* 4. An AC reactor is required between Converter and main circuit power supply.
* 5. Temperature during shipping.