Specifications
14.1.2 Winding Selection Drive Series
14 -8
Table 14.4 Winding Selection 400 V Series
Model UAASK FZ***E
B-06 B-08 B-11 B-15 B-19 B-22 B-30
*1
Rated
*2
30-minute Rating (S2)
50%ED Rating (S3)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
30
(22)
40
(30)
u
pu
HP (kW)
Continuous Rating
(S1)
5
(3.7)
7.5
(5.5)
10
(7.5)
15
(11)
20
(15)
25
(18.5)
27
(20)
Rated
Base Speed 500 400
spee
(min
−1
)
Maximum Speed 6000 4800
N·m 71 105 143 262 358 442 477
Motor
Output Torque at Base
Speed Continuous Rating
lb·ft
(kgf·m)
52.3
(7.21)
77.6
(10.7)
105.9
(14.5)
193.6
(26.7)
264.5
(36.5)
326.2
(45.0)
351.8
(48.7)
Rotor Inertia J (GD
2
/4) lb·ft
2
(kg·m
2
)
1.614
(0.068)
1.970
(0.083)
2.563
(0.108)
6.146
(0.259)
11.22
(0.473)
13.00
(0.548)
13.00
(0.548)
Overload Capacity 120%, 60s of 30-minute rating
Vibration (µ·m)
V5 V10
Noise Level 75dB (A) or less 80dB (A) or less
Ambient Temperature, Humidity
0°Cto40°C (32°F to 104°F), 95% or less (non-condensing)
Approx. Mass lb
(kg)
207
(94)
238
(108)
291
(132)
481
(218)
783
(355)
893
(405)
893
(405)
Model CIMR-M5j
*
3
45P5 47P5 4011 4015 4018 4022 4030
Continuous Rated Input Current
(A)
8.8 13.1 17.9 26.2 35.7 44.1 52.4
Continuous Rated Output Current
(A)
10.4 15.5 20 28 40 49 56.5
Control Method Sine wave PWM Inverter (Vector control)
r
Speed Control Range 40 min
−1
to maximum motor speed
erte
Speed Regulation 0.2% maximum speed or less
Inv
Overload Capacity 120%, 60s of 30-minute rating
Approx. Mass lb (kg) 11 (5) 27 (12) 35 (16)
Applicable Magnetic Contactor
Model
HV-75AP4 HV-150AP4
Width 3.94 (100) 5.91 (150) 9.84 (250)
Dimensions in inches
*4
Height 13.78 (350)
mm
Depth 12.60 (320)
r
Model CIMR-MR5j
*
3
45P5 47P5 4011 4015 4018 4022 4030
oller
Required Power Capacity (kVA) 9 12 19 24 30 36 48
Contr
Continuous Rated Input Current
(A)
6.7 9.85 13.4 19.7 26.8 33.1 39.3
Continuous Rated Output Current
(A)
8.8 13.1 17.9 26.2 35.7 44.1 52.4
5
Power Supply
Three-phase, 400 VAC (50/60Hz); 440 VAC (50/60Hz); 460 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%,
Line-to-line voltage unbalance: 5% or less)
onverter
*
5
Control Power Supply
Single-phase, 200 VAC (50/60Hz); 220 VAC (50/60Hz); 230 VAC (60Hz)
(Allowable voltage fluctuation: +10% to −15%, allowable frequency fluctuation: ±5%)
Required power capacity: 100 VA (for independent drive system)
250 VA (for NC system)
C
Control Method
Power regenerative control (120_ current conduction)
Overload Capacity 120% for one minute, 200% for one second
Approx. Mass lb (kg) 11 (5) 27 (12) 46 (21)
Width 3.94 (100) 5.91 (150) 9.84 (250)
Dimensions in inches
*4
Height 13.78 (350)
mm
Depth 12.60 (320)
Power Supply AC Reactor Code
No.
X002501 X010099 X010100 X010101 X010102 X010103 X010104
14