Phone Customization
187
Default 1
Web UI Settings->Power Saving->Power Saving
Parameter features.power_saving.office_hour.idle_timeout <y0000000000xx>.cfg
Description
It configures the time (in minutes) to wait in the idle state before IP phone enter power-saving mode dur-
ing the office hours.
Example:
features.power_saving.office_hour.idle_timeout = 600
The IP phone will enter the power-saving mode when it has been inactivated for 600 minutes (10 hours)
during the office hours.
Note: It is not applicable to T19(P) E2 IP phones.
Permitted
Values
Integer from 1 to 960
Default 960
Web UI Settings->Power Saving->Office Hour Idle TimeOut
Parameter features.power_saving.off_hour.idle_timeout <y0000000000xx>.cfg
Description
It configures the time (in minutes) to wait in the idle state before IP phone enter power-saving mode dur-
ing the non-office hours.
Example:
features.power_saving.off_hour.idle_timeout = 5
The IP phone will enter the power-saving mode when it has been inactivated for 5 minutes during the
non-office hours.
Note: It is not applicable to T19(P) E2 IP phones.
Permitted
Values
Integer from 1 to 10
Default 10
Web UI Settings->Power Saving->Off Hour Idle TimeOut
Parameter features.power_saving.user_input_ext.idle_timeout <y0000000000xx>.cfg
Description
It configures the minimum time (in minutes) to wait in the idle state - after using the phone - before the
IP phone enters the power-saving mode.
Example:
features.power_saving.user_input_ext.idle_timeout = 5
Note: It is not applicable to T19(P) E2 IP phones.
Permitted
Values
Integer from 1 to 30
Default 10
Web UI Settings->Power Saving->User Input Extension Idle TimeOut
Parameter features.power_saving.office_hour.monday <y0000000000xx>.cfg