Target setpoints 1 to 8
COM
Anaolog input
*1
Output limiter
Manual operation
Manual preset output
Input error preset output
Preset output
AUTO (ON)/MAN (OFF) switch
STOP (ON)/RUN (OFF) switch
LOCALREMOTE
AUTO
When sensor burnout occurs
Normal
MAN
RUNSTOP
SP ramp rate
SP limiter
DI16PV RSP AIN2
Input type
Input unit
Input range/scale
Analog input bias
Square root extraction
Analog input filter
Input type
Input unit
Input range/scale
Analog input bias
Square root extraction
Analog input filter
10-seg. linearizer approx./bias
Remote input filter
PV input bias
PV input filter
Ratio bias computation
Output limiter
A.BS
A.FL
BS
FL
PMD An, Bn
10-seg. linearizer approx./bias
PMD An, Bn
PMD An, Bn
CNT ALG
UPR, DNR TMU
SPNO SP
RT RBS
Filter
Gain, bias
FLG
FGN
FBI FBO
R/L
RMS
SPH, SPL
RFL
A.SR A.LC
UNIT
IN
RH, RL SDP SH, SL
A.BS
A.FL
10-seg. linearizer approx./bias
A.SR A.LC
UNIT
IN
RH, RL SDP SH, SL
EPO
OH, OL
OH, OL OLMT
PO
S/R
MPON
OT
Equipped as standard
Equipped as standard
Heater break alarm
HAL2HAL1
Heater break
alarm 1
Heater break
alarm 2
Current or voltage pulseRelay
LPS
24 V loop
power supply
Current
OUTOUT RET AL3AL2AL1
PMD
OU.H OU.L
An, Bn
Split computation
10-seg. linearizer approx./bias
RET.H RET.L
PMD An, Bn
Split computation
10-seg. linearizer approx./bias
OUT retransmission output
O1RS
RET retransmission output
RTS
* After the control output terminal is specified by the parameter OT,
other current output terminals can be used as retransmission output.
Alarm
Output terminal assignment
DI3DI2DI1
A/M
No function
is assigned
to DI3.
REMOTE (ON)/LOCAL (OFF)
switch
Control computation
(Current when retransmission output)
Input type
Input unit
Input range/scale
Analog input bias
Square root extraction
Analog input filter
PMD An, Bn
A.BS
A.FL
10-seg. linearizer approx./bias
A.SR A.LC
UNIT
IN
RH, RL
SDP
SH, SL
Communication
*1: RS-485, Ethernet, PROFIBUS-DP,
DeviceNet, CC-Link
PV input Remote input Feedforward input Contact inputs
Equipped as standard
Terminal Parameter Function
Analog signal Contact signal Front panel key
Legend
Alarm 1
(PV high limit)
Alarm 2
(PV low limit)
Alarm 3
(PV high limit)
PV display SP display
Input ladder calculation program (signal goes to the control computation as is when without ladder program). For ladder program, see the LL50A Parameters Setting Software User’s Manual.
Output ladder calculation program (signal goes to the output as is when without ladder program). For ladder program, see the LL50A Parameter Setting Software User’s Manual.
Universal input (E1-terminal area) can be used
when UT55A/UT52A optional suffix code /U1.
However, DI16 does not exist.
(For Detailed model)
Remote input can be used when UT55A/UT52A
optional suffix code /R1 or /RCH1.
(For Standard model)
Remote input can be used when UT55A suffix
code: Type 2 = 1, 2, 4, 5, or 7; UT52A suffix
code: Type 2 = 1 or 2.
(For Detailed model)
Feedforward input can be used when
UT55A optional suffix code /A2.
(For Standard model)
Feedforward input can be used when
UT55A suffix code: Type 2 = 7.
(For Detailed model)
DI16 is equipped when UT55A/UT52A
optional suffix code /R1 or /RCH1.
(For Standard model)
DI16 is equipped when
UT55A suffix code: Type 2 = 1, 2, 4, 5, or 7;
UT52A suffix code: Type 2 = 1 or 2.