Communication
Target setpoints 1 to 8
COM
Aux. input
*1
LOCALREMOTE
SP ramp rate
SP limiter
Loop-1 PV input
Equipped as standard
* The LP2 lamp is lit while the Loop-2 parameter is displayed.
Loop-2 PV input
DI2 DI3DI1 DI16PV RSP
Input type
Input unit
Input range/scale
Analog input bias
Square root extraction
Analog input filter
Input type
Input unit
Input range/scale
Analog input bias
Square root extraction
Analog input filter
10-seg. linearizer approx./bias
PV input bias
PV input filter
Ratio bias computation
Contact inputs
A.BS
A.FL
BS
FL
PMD An, Bn
10-seg. linearizer approx./bias
PMD An, Bn
10-seg. linearizer approx./bias
PV input bias
PV input filter
BS
FL
PMD An, Bn
CNT ALG
UPR, DNR TMU
SPNO
SPNO
SP
R/L
RMS
SPH, SPL
UPR, DNR
C/A/M
SPH, SPL
RFL
A.SR A.LC
UNIT
IN
RH, RL
SDP
SH, SL
A.BS
A.FL
A.SR A.LC
UNIT
IN
RH, RL
SDP
SH, SL
AIN2
PMD An, Bn
A.BS
A.FL
A.SR A.LC
UNIT
IN
RH, RL
SDP
SH, SL
Tracking signal (Tracking when not in Cascade)
AUTO, MAN
AUTO, MAN
CAS
CAS
Switch to AUTO when
Loop-1 PV input burnout
or A/D error occurs.
Loop-2 target setpoints
OH, OL
SP ramp rate
SP limiter
RUNSTOP
S/R
Remote input filter
Output limiter
Cascade (OFF→ON)
Automatic (OFF→ON)
Manual (OFF→ON)
STOP (ON)/RUN (OFF) switch
STOP (ON)/RUN (OFF) switch
STOP (ON)/RUN (OFF) switch
Loop-1 control computation
Loop-2 control computation
For the model with optional suffix code /DR:
Remote input with direct input (E1-terminal area)
can be used when
UT55A suffix code: Type 2 = 1, 2, 4, 5, or 7 and
with optional suffix code /DR;
UT52A suffix code: Type 2 = 1 or 2 and
with optional suffix code /DR.
However, DI16 is to be deleted.
Manual operation
Manual preset output
Input error preset output
Heating-side preset output
STOP (ON) /RUN (OFF) switch
Normal Normal
MAN
RUNSTOP
Current or
voltage pulse
Relay Current or
voltage pulse
Relay
LPS
24 V loop
power supply
Current
EPO
OH, OL OHc, OLc
Input error preset output
OUT retransmission output OUT2 retransmission output
EPO
PO
Cooling-side preset output
STOP
POc
S/R
OT
O1RS O2RS
RET retransmission output
RTS
MPON
Heating-side
output
Heating-side
output
Cooling-side
output
Cooling-side
output
OUTOUT OUT2 OUT2
Heating/cooling computation
RET
* After the control output terminal is specified by the parameter OT,
other current output terminals can be used as retransmission output.
AL3AL2AL1
Terminal Parameter Function
Analog signal Contact signal Front panel key
Legend
Heating-side output limiter Cooling-side output limiter
RUN
Output terminal assignment
PMD
OU.H OU.L OU2.H OU2.L
An, Bn PMD An, Bn
Split computation
10-seg. linearizer approx./bias
Split computation
10-seg. linearizer approx./bias
RET.H RET.L
PMD An, Bn
Split computation
10-seg. linearizer approx./bias
Alarm
CAS, AUTO
C/A/M
Equipped as standard
Equipped as standard
A/M
Alarm 1
(Loop-1 PV high limit)
Alarm 2
(Loop-1 PV low limit)
Alarm 3
(Loop-1 PV high limit)
(Current when retransmission output) (Current when retransmission output)
When Loop-2 sensor
burnout occurs
When Loop-2 sensor
burnout occurs
PV display
SP display
Input ladder calculation program (signal goes to the control computation as is when without ladder program). For ladder program, see the LL50A Parameter Setting Software User’s Manual.
PV display
SP display
Output ladder calculation program (signal goes to the output as is when without ladder program). For ladder program, see the LL50A Parameter Setting Software User’s Manual.
Manual output is prioritized even if
sensor
burnout
occurs in MAN.
Aux. analog (remote) input
Input type
Input unit
Input range/scale
Analog input bias
Square root extraction
Analog input filter
10-seg. linearizer approx./bias
*
*
An external analog signal can
be used for Loop-2 SP. Use
the ladder program of LL50A
Parameter Setting Software
to build the function.
*1: RS-485, Ethernet, PROFIBUS-DP,
DeviceNet, CC-Link
**
**
**
**
**
**
**
** **
** **
Loop-2 parameters
Universal input (E1-terminal area) can be used
when UT55A/UT52A optional suffix code /U1.
However, DI16 does not exist.
(For Standard model)
Remote input can be used when UT55A
suffix code: Type 2 = 7.
(For Detailed model)
Remote input can be used when UT55A
optional suffix code /A2.
(For Standard model)
UT55A suffix
code: Type 2 = 1, 2, 4, 5, or 7; UT52A
suffix code: Type 2 = 1 or 2 is necessary.
(For Detailed model) UT55A/UT52A
optional suffix code /R1
or /RCH1 is
necessary.
(For Standard model)
DI16 is equipped
when UT55A suffix code: Type 2 = 1, 2, 4,
5, or 7; UT52A suffix code: Type 2 = 1 or 2.
(For Detailed model)
DI16 is equipped
when
UT55A/UT52A optional suffix
code /R1 or /RCH1.