4 - 24 MP7000 Scanner Scale Integrator Guide
Successfully 
entering scale 
legal Calibration 
Mode 
Step 3 - Program 
Legal Parameters
 
and 
Step 4 - 
Calibration at NO 
LOAD
 - Scrolls 
C00Lb
 OR 
C00g
 
depending on units 
programmed as 
pounds (lb) or 
kilograms (kg) 
Step 5 - Calibration at 
LOAD
 - Scrolls 
C25Lb
 or 
C11g
 
depending on units 
programmed as 
pounds (lb) or 
kilograms (kg)
Step 6 - Calibration 
Success or Failure
 - 
Repeat scrolls of 
CALP
 then 
CALS
Any step - Calibration 
Fails - Scrolls fault 
code: 
u##
No change Five long beep 
tones
Off
Step 4 - Calibration at NO 
LOAD
Blinks between CAL00 and 
then CAL_ _ with correct 
unit icon illuminated (lb or 
kg).
Step 5 - Calibration at 
LOAD
Blinks CAL25 with lb icon 
illuminated, or blinks CAL11 
with kg icon illuminated.
Step 6 - Calibration 
Success or Failure
Blinks between CAL P 
(PASS) and CAL S (save 
legal parameter settings). 
Any step - Calibration fails 
blinks CAL F.
Between 
calibration steps
No change No change No change Off Blinks HOLD while taking a 
measurement.
Stepping through 
a calibration step 
No change No change Single long beep 
tone after 
pressing the 
Scale Zero
 
button
Off No change
Failure to place 
the correct load 
on the scale at 
Step 5 - 
Calibration at 
LOAD
C25Lb
 or 
C11g
 
depending on units 
programmed
No change Two long beep 
tones
No change No change
Successfully 
executing and 
exiting a scale 
legal calibration
Calibration procedure 
semantics removed 
from display. 
No change Three short 
beeps
Solid green 
on if weight 
stable after 
reset of 
scale
Scale is reset either by 
pressing the 
Scale Zero
 
button, scanning the 
Scale 
Reset
 parameter barcode, 
or powering the unit OFF 
then ON. The seven 
segment test will run. 
Table 4-6    LED and Beeper Sequences (Continued)
Scale State
7-segment 
Diagnostic Display
LED 
(System)
Beeper 
Sequence
Scale Zero 
Button 
(LED)
Optional Scale Display