Scale Calibration (For Models With a Scale) 4 - 25
Cold reset of
scale
No change No change No change
except at
Step 6
- Calibration
Success or
Failure
- when
the
Scale Zero
button is
pressed three
short beeps
tones sound
No change Seven segment test runs
and displays:
00.000 all icons
illuminated for three
seconds
Blank for one second
99.999 all icons
illuminated for three
seconds
Blank for one second
Normal display
Audit Tally -
Press and hold
Scale Zero
button for greater
than three
seconds when
not in a
Calibration
Mode.
Repeated scroll:
C###
then
P###
No change None No change Blinks between C### and
P###.
In Bootloader
Mode
No change Off None Off None.
Scale Error Scrolls fault code:
u##
Red
(Warning)
None Off Blinks FAIL or blanks
display with unit icon
showing lb or kg
illuminated.
Display can also blink
CALF if the system was in a
scale legal Calibration
Mode.