Operating the Scanner 5 - 19
Press and hold/release
Scale Zero
and
EAS
buttons
Click Red after 10
seconds
upon reboot
No change After buttons are held for 10
seconds, a system reboot initiates.
Press and hold
Scale
Zero
and
Volume/Tone
buttons for 5 seconds,
then release
Short beep after
5 seconds;
within 2
seconds of
release, press
the
Scale Zero
and
Volume/Tone
again and
release; 5 long
beeps sound
No change No change After final 5 long beeps sound, scale
calibration is entered.
Press and release
EAS
button
Click No change EAS is
enabled, LED
is amber
If EAS is enabled, button press
activates tag manual deactivation.
Camera Activation Button Presses
Press and release the
Camera Activation
button
Periodic clicks
until shutter
sounds
indicating a
picture was
taken
No Change No Change Takes a picture.
Press-hold-release
(hold longer than 0.5
seconds) the
Camera
Activation
button to
scan a bank check.
Periodic clicks
until check scan
completes.
Successful
completion -
one beep
sounds.
Unsuccessful
completion -
four beep
sequence
sounds.
No Change No Change Scans a bank check.
Code 39 Buffering
Code 39 character
added into buffer
High, Low
Beeps
No change No change New Code 39 data was entered into
the buffer.
Code 39 buffer full 3 Long High
Beeps
No change No change Code 39 buffer is full.
Table 5-1 Beeper and LED Indicators (Continued)