186 Parameters
01.10 POS ACT
Shows the actual position of the encoder. - / Real
-51445.760...
51445.760 m
Encoder position. - /
1000 = 1 m
01.11 SPEED
ESTIMATED
Shows the estimated motor speed. - / Real
-30000.00...
30000.00 rpm
Motor speed in rpm. - /
100 = 1 rpm
01.12 TEMP INVERTER
Shows the measured temperature of heatsink in
percent of maximum allowed temperature.
- / Real24
-40.0...160.0 % Heatsink temperature in percent of maximum allowed
temperature.
10 = 1 % / -
01.13 TEMP BC
Shows the brake chopper IGBT temperature in
percent of maximum allowed temperature.
- / Real24
-40.0...160.0 % Brake chopper IGBT temperature in percent of
maximum allowed temperature.
10 = 1 % / -
01.14 MOTOR TEMP
Shows the measured motor temperature when a KTY
sensor is used.
Note: With a PTC sensor, the value is always 0.
- / Real
-10.0...250 °C Measured motor temperature in Celsius 10 = 1 °C / -
01.15 USED SUPPLY
VOLT
Shows the automatically determined supply voltage. - / Real
0.0...1000.0 V Used supply voltage. 10 = 1 V / -
01.16 BRAKE RES TEMP
Shows the estimated temperature of the brake
resistor.
The value is given in percent of temperature the
resistor reaches when loaded with the power defined
by parameter 48.03 BR POWER MAX CNT.
- / Real24
0...1000% Brake resistor temperature in percent. 1 = 1% / -
01.17 CPU USAGE
Shows the microprocessor load in percent. - / UINT32
0...100% CPU usage. 1 = 1%/ -
01.18 INVERTER
POWER
Shows the drive output power. - / Real
-32768.00...
32768.00 kW
Drive output power
in kilowatts.
- /
100 = 1 kW
01.19 ON TIME
COUNTER
Counts the time the drive is powered On.
The counter runs only when drive is powered. The
value is protected against power failure.
The counter can be reset using the DriveStudio tool.
The counter can only be set to zero.
- / INT32
0.0...
35791394.1 h
Drive power On time in hours.
- / 10 = 1 h
No. Bit/Name/Value/
Range
Description Def/Type
FbEq
(16b/32b)