Transferring the memory unit to a new drive module
When a drive module is replaced, the parameter settings can be retained by
transferring the memory unit from the defective drive module to the new module.
WARNING! Do not remove or insert the memory unit when the drive module
is powered.
After power-up, the drive will scan the memory unit. If a different application program
or different parameter settings are detected, they are copied to the drive. This may
take a few moments; the LED display readsL” while copying is in progress. See The
7-segment display on the JCU control unit on page 73.