Using the control panel 103
Changing bit pointer parameter value to 0 or 1
The bit pointer parameter can be fixed to constant value of 0 (FALSE) or 1 (TRUE).
When adjusting a bit pointer parameter on the control panel, CONST is selected to fix
the value to 0 (displayed as C.FALSE.) or 1 (C.TRUE.).
Step Action Display
1. Go to the Main menu by pressing if you are
in the Output mode, otherwise by pressing
repeatedly until you get to the Main menu.
2. Go to the Parameters option by selecting
PARAMETERS on the menu with keys and
, and pressing .
3. Select the appropriate parameter group with keys
and . Here the bit pointer
parameter 12.04 DI01 OUT PTR is used as an
example.
4. Press to select the appropriate parameter
group. Select the appropriate parameter with keys
and . The current value of each
parameter is shown below its name.
5. Press .
Select CONST with keys and .
MENU
EXIT
PARAMETERS
FAULT LOGGER
TIME & DATE
EXIT ENTER
00:00
MAIN MENU 1LOC
ENTER
01 ACTUAL VALUES
02 I/O VALUES
03 CONTROL VALUES
05 LIFT CTRL SIGNALS
06 DRIVE STATUS
EXIT
SEL00:00
PAR GROUPS 01LOC
12 DIGITAL IO
13 ANALOGUE INPUTS
15 ANALOGUE OUTPUTS
16 SYSTEM
20 LIMITS
EXIT
SEL00:00
PAR GROUPS 12
LOC
SEL
1201 DI01 CONF9901
1202 DI02 CONF
1203 DI03 CONF
1204 DI01 OUT PTR
P.06.02.02
PARAMETERS
EXIT
EDIT
00:00
LOC
EDIT
1204 DI01 OUT PTR
PAR EDIT
Pointer
CANCEL NEXT
00:00
LOC
1204 DI01 OUT PTR
PAR EDIT
Const
CANCEL NEXT
00:00
LOC