General safety instructions for personnel installing, starting up, and maintaining the drive.
Specific electrical safety precautions before performing work on the drive.
Instructions and requirements for proper grounding of the drive and associated equipment.
Safety instructions for all personnel operating the drive.
Explanation of the drive's operating principle and main circuit components.
Details on drive module dimensions and necessary free space for installation.
Guidelines for ensuring adequate cooling and protection levels for the drive in a cabinet.
Requirements and checks for the installation site before mounting the drive.
Methods for implementing thermal overload and short-circuit protection for the drive.
Checklist to verify the correct installation of the drive module.
Procedure for initial drive start-up, including motor data entry.
Instructions for entering motor nameplate data for accurate control.
Procedure for performing motor identification to optimize motor control.
Guide on how to view and change parameter values on the control panel.
Step-by-step process for selecting and modifying parameter values.
Accessing and viewing drive fault history and details.
Methods for resetting drive faults via the control panel or external signals.
Functionality for backing up and restoring drive parameters to/from the control panel.
Detailed steps for performing parameter backup and restore operations.
Description of the integrated Safe Torque Off (STO) function.
Procedures for backing up and restoring drive settings and configurations.
Information on restoring parameters, including potential failure reasons.
Functions for basic elevator start/stop control and interlocks.
Classification of drive faults as critical or non-critical.
Configuration and operation of the automatic fault reset function.
Mode used for maintenance operations, allowing controlled elevator movement.
Functionality for setting and scaling speed references for elevator operation.
Optimizing travel time by reducing the leveling path using smart slowdown.
Functions to ensure proper operation under various conditions like speed match and motor stall.
Checks if motor speed follows the speed reference within a desired window.
Protects the motor in stall situations by monitoring torque limits.
Configuration of various drive protection functions like phase loss and earth fault.
Information on the two available emergency stop functions (OFF1 and OFF3).
Procedure for elevator car rescue during power supply failure.
Drive operation during evacuation, including manual and automatic modes.
Methods for setting parameters via control panel, DriveStudio, or fieldbus.
Methods for resetting the drive after a fault or alarm condition.
Information on how the drive stores and logs the 16 latest faults.
Table of alarm codes, causes, and recommended actions for troubleshooting.
Information about the drive's support for the Safe Torque Off function.
Rules and tables for selecting a brake resistor based on calculated values.