RS485 connector pinouts
The arrangement for the pins in the RS485 connector (figure 533) are presented in
table 706:
Table 706: The arrangement for the pins
Pin Name 2-wire Name 4-wire Description
1 RS485+ TX+ Receive/transmit high or transmit high
2 RS485– TX– Receive/transmit
3 Term T-Term Termination resistor for transmitter (and receiver in 2–
wir case) (connect to TX+)
4 N.A. R-Term Termination resistor for receiver (connect to RX+)
5 N.A. RX– Receive low
6 N.A. RX+ Receive high
Screw
terminal
X3
1
2
1
2
3
4
5
6
Screw
terminal
X1
Backplane
Angle
bracket
RS485
PWB
IEC06000517 V1 EN
Figure 533: RS485 connector
2-wire: Connect pin 1 to pin 6 and pin 2 to pin 5
Termination (2-wire): Connect pin 1 to pin 3
Termination (4-wire): Connect pin 1 to pin 3 and pin 4 to pin 6
Soft ground connector pinouts
A second 2-pole screw connector is used for the connection of IO-ground. It can be
used in two combinations like: