10 Serial Decode/Lister
322 InfiniiVision Oscilloscopes User’s Guide
Viewing MIL-STD 1553 Data in the Lister
1 In the Serial Decode Menu (when serial decode is being displayed), press Lister.
2 In the Lister Menu, press Lister Display to turn it on.
In addition to the standard Time column, the MIL-STD 1553 Lister contains these
columns:
RTA – displays the Remote Terminal Address for Command/Status words, nothing for
Data words.
Word Type – “Cmd/Status” for Command/Status words, “Data” for Data words. For
Command/Status words the background color is green to match the decode text color.
Data – the 11 bits after the RTA for Command/Status words, or the 16 bits of a Data
word.
Errors – “Sync”, “Parity”, or “Manchester” errors as appropriate. The background
color is red to indicate an error.
For more information on using the Lister display, see “Lister” on page 293.