VLL Services
7705 SAR OS Services Guide Page 231
— [no] ccm-enable
— ccm-ltm-priority priority
— [no] ccm-ltm-priority
— [no] dual-ended-loss-test-enable
— alarm-threshold percentage
— [no] alarm-threshold
— [no] eth-test-enable
— [no] test-pattern {all-zeros | all-ones} [crc-
enable]
— low-priority-defect {allDef | macRemErrXcon |
remErrXcon | errXcon | xcon | noXcon}
— [no] shutdown
—ethernet
— [no] llf
— ingress
— filter ip ip-filter-id
— no filter [ip ip-filter-id]
— qos policy-id
—no qos
— service-mtu octets
—no service-mtu
— [no] s
hutdown
— spoke-sdp sdp-id:vc-id [vc-type {ether | vlan}] [create] [no-endpoint]
— spoke-sdp sdp-id:vc-id [vc-type {ether | vlan}] [create] endpoint endpoint-name
—no spoke-sdp sdp-id:vc-id
— [no] control-word
— egress
— vc-label egress-vc-label
—no vc-label [egress-vc-label]
— eth-cfm
— mep mep-id domain md-index association ma-index
[direction {up | down}]
—no mep mep-id domain md-index association ma-index
— [no] ccm-enable
— ccm-ltm-priority priority
— [no] ccm-ltm-priority
— low-priority-defect {all
Def | macRemErrXcon |
remErrXcon | errXcon | xcon | noXcon}
— [no] shutdown
— ingress
— vc-label ingress-vc-label
—no vc-label [ingress-vc-label]
— [no] shutdown
— precedence [precedence-value | primary]
—no precedence
— vlan-vc-tag 0..4094
—no vlan-vc-tag [0..4094]
Note: The spoke-sdp configuration does not apply to Ethernet SAP-to-SAP configuration
(local service). It only applies to SAP-to-SDP configuration (distributed service).