Environmental and electrical characteristics
MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01 103
3.7.2 — General characteristics (MPT-HC/HC-HQAM/MC/XP/XP-
HQAM/9558HC)
Table 3.4 — General characteristics (MPT-HC/HC-HQAM/MC/XP/XP-HQAM/9558HC)
General with MPT-HC V2/HC-HQAM/9558HC
Operating Frequency Range 5.8 - 38 GHz
Max. Ethernet throughput MPR-E: 339.834 Mb/s
MPR-A: 314.46 Mb/s
Bandwidth MPR-E: up to 56 MHz
MPR-A: up to 50 MHz
Modulation Options in FCM QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Adaptive Modulation QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
General with MPT-XP/XP-HQAM
Operating Frequency Range 6 - 8 GHz
Max. Ethernet throughput 349 Mb/s
Bandwidth MPR-E: up to 56 MHz
MPR-A: up to 50 MHz
Modulation Options in FCM QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Adaptive Modulation QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
General with MPT-MC (MPR-E)
Operating Frequency Range 6 - 38 GHz
Max. Ethernet throughput 349 Mbps
Bandwidth up to 56 MHz
Modulation Options in FCM QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Adaptive Modulation QPSK, 8PSK, 16 QAM, 32 QAM, 64 QAM, 128 QAM, 256 QAM
Radio Path Protection Options
Non Protected, 1+0
Standards Compliance
EMC EN 301 489-1, EN 301 489-4, EN 55022 Class B
Stationary use ETS 300 019, Class 4.1
Storage ETS 300 019, Class 1.2