Functional description
MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01 131
3.9.7.3.1 MPT-HC/MPT-XP optical interface
3.10 Functional description
3.10.1 MSS-1c (indoor unit)
The MSS-1c incorporates the base–band processing and also radio interface functionalities
only when the MPT-HC/HC V2/HC-HQAM/MC/XP/XP-HQAM/9558HC is connected.
MSS-1c offers tributaries interfaces as well as supervision.
The MSS-1c is frequency–independent.
OMT 23 GHz 3CC58165AAXX
Table 3.36 MPT-HC/HC-HQAM/XP/XP-HQAM OMT couplers for MPR-e
Description Codes
Table 3.37 MPT-HC/HC-HQAM/XP/XP-HQAM optical interface
Description Codes Remarks
SFP 1000Base-Sx Transceiver 1AB383760001/
3CC50167AAAA
Optical SFP module to be installed optionally
in the MPT to provide the optical interface
SFP 1000Base-Lx Transceiver 1AB383760002/
3CC50168AAAA