Functional description
MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01 155
3.10.8.9 Link identifier
The number of microwave links, especially in urban areas, might cause interference during
installation and the turn-up phase.
The digital frame incorporates link identity coding capabilities to prevent the capture of an
unwanted signal.
If a “Link Identifier Mismatch” occurs all traffic is dropped.
The Link identifier management function can be enabled or disabled by the management
system.
3.10.8.10 Loopbacks
To facilitate installation/commissioning and remote maintenance, two loopbacks are
available.
As the activation of a loopback affects traffic, the presence of a loopback is indicated to the
management systems as an abnormal condition.
The supported loopbacks are shown in Figure 3.65.
Figure 3.65 Available loopbacks
The following loopbacks are provided by the MPT-HC/HC-HQAM/MC/XP/XP-HQAM:
Line Side loopback: this loopback routes data from the output of the Tx Data
Awareness block (after compression) to the input of the Rx data awareness block
(decompression). This is an internal loopback.
It is a Loop and Continue loopback. It is possible to enable this loopback only at
aggregate level.
When this loopback is activated, the behavior is as follows: