Environmental and electrical characteristics
MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01 115
3.7.7 — Radio performances
3 MPT MPT-HC + XPIC
(MPR-e only)
141.0 W 141.0 W 141.0 W 141.0 W 141.0 W 141.0 W
Cable Losses 5.7 W 12.9 W 21.6 W 39.3 W 14.1 W 34.5 W
Power Unit 6.0 W 6.0 W 6.0 W 6.0 W 6.0 W 6.0 W
Total power
consumption
152.7 W 159.9 W 168.6 W 186.3 W 161.1 W 181.5 W
MPT-HC-HQAM +
XPIC
(MPR-e only)
121.5 W 121.5 W 121.5 W 121.5 W 121.5 W 121.5 W
Cable Losses 5.7 W 12.9 W 21.6 W 39.3 W 14.1 W 34.5 W
Power Unit 6.0 W 6.0 W 6.0 W 6.0 W 6.0 W 6.0 W
Total power
consumption
133.2 W 140.4 W 149.1 W 166.8 W 141.6 W 162.0 W
4 MPT MPT-HC + XPIC
(MPR-e only)
188.0 W 188.0 W 188.0 W 188.0 W 188.0 W 188.0 W
Cable Losses 7.6 W 17.2 W 28.8 W 52.4 W 18.8 W 46.0 W
Power Unit 8.0 W 8.0 W 8.0 W 8.0 W 8.0 W 8.0 W
Total power
consumption
203.6 W 213.2 W 224.8 W 248.4 W 214.8 W 242.0 W
MPT-HC-HQAM +
XPIC
(MPR-e only)
162.0 W 162.0 W 162.0 W 162.0 W 162.0 W 162.0 W
Cable Losses 7.6 W 17.2 W 28.8 W 52.4 W 18.8 W 46.0 W
Power Unit 8.0 W 8.0 W 8.0 W 8.0 W 8.0 W 8.0 W
Total power
consumption
177.6 W 187.2 W 198.8 W 222.4 W 188.8 W 216.0 W
Table 3.15 — MPT-HC power system: power requirements
Cable type
P/N
Coaxial Cable 1AC001100022 Coaxial Cable
1AC041350001
Cable Length 0 - 100 m 100 - 200 m 200 - 300 m 300 - 440 m 0 - 100 m 100 - 190 m
Number
of MPT
ODU
Input Voltage for
Power Unit
-38.4
(Vdc)
38.4 (Vdc) 38.4 (Vdc) 38.4 (Vdc) 38.4
(Vdc)
38.4 (Vdc)