9500 family overview
64 MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01
In case of electrical radio interface, on the same cable is also sent the power supply for the
MPT by using the Power Feed over Ethernet (PFoE) function.
For the different connection solutions with the MPTs, see MSS-1c to MPT-HC/HC-
HQAM/9558HC interconnection, and MSS-1c to MPT-MC interconnection.
3.1.4 MPR-e
3.1.4.1 Ethernet generic device prerequisites
One Ethernet traffic port:
electrical to be used with MPT-HC V2/HC-HQAM/MC/XP/XP-HQAM or
optical only with MPT-HC V2/HC-HQAM/XP/XP-HQAM
An FE (minimum) port
For local management (provisioning phase only):
VLAN management capability to create a tagged service between the local
management port and MPT Ethernet port
One service open with VLAN ID on GE Port. Default VLAN ID: 4080
If local management is not required, the NE could be supervised through TMN RF.
One Gigabit Ethernet (GE) traffic port:
electrical to be used with MPT-HC V2/HC-HQAM/MC/XP/XP-HQAM or
optical only with MPT-HC V2/HC-HQAM/XP/XP-HQAM
For local management (provisioning phase only):
An FE (minimum) port
VLAN management capability to create a tagged service between the local
management port and MPT Ethernet port
One service open with VLAN ID on GE Port. Default VLAN ID: 4080
If local management is not required, the NE could be supervised through TMN RF.
Note: The MPT-HCMPT-HC/HC-HQAM/MC/XP/XP-HQAM/9558HC (MPR-A) can be
connected also by using an optical cable for the Ethernet traffic and a coaxial cable for
the power supply.