262 MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01
To configure a TDM cross connection between radio and Ethernet port:
Push button Add cross-connection and fill the fields.
In column User port: Select a port in the list
In column Flow Id: Enter a valid VLAN Id (between 2 and 4080). This VLAN Id
must be equal to the one used to encapsulate PDH flows at the transmitter side
In column Service Profile: Select TDM2TDM or TDM2ETH, also equal to what is
configured at transmitter side
In column TDM Clock Sync: Select Differential or Adaptive in the list. The clock
sync is also equal to what is configured at transmitter side: Differential or Adaptive
In column Outgoing MAC destination: enter the MAC address of the destination
equipment.
Note that Outgoing MAC Source address, which is equal to the NE MAC address,
is displayed for information and will be used with the previous one to generate the
cross connection inside the switch.
The following picture represents the elements involved in the cross connection, here only
the switch. In blue the Ethernet part realized by the switch.
Figure 4.83 Cross connection functional scheme