280 MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01
Figure 4.101 TMN RF field
NMS1/NMS2 fields (MSS-1c only)
Assign the IP parameters to the 10/100Base-T 2 Ethernet ports (if required) for NMS
application.
NE IP Parameters field
This IP address is the local IP address. The default IP address is: 10.0.1.2. The subnet
mask is 255.255.255.255(/32) and cannot be changed.
TMN In-band IP parameters
Enter the IP Address with the relevant subnet mask for TMN In-band management.
The VLAN Id can be changed only with the Provisioning Tool (value between 2 and
4080). Default IP addresses: 192.168.100.1. Default subnet mask: 255.255.255.0(/
24).
In the VLAN ID field enter the VLAN ID used for In-band management (default:
4080).
Note: The TMN RF in-band Van ID must be different from the one configured for User
Ethernet TMN in-band.
You need to ensure the consistency of the TMN RF configuration at both ends of the radio
interface, otherwise the TMN RF in-band link will not set up.
Note: In case of change of NMS1 (or 2) IP address previously used for NMS2 (or 1), proceed
in 2 steps: disable NMS2 (or 1) and apply the configuration then change NMS1 (or 2) and
apply the configuration.
Warning: NMS1 and NMS2 must be also enabled through MSS-1c Provisioning Tool.