208 MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01
Figure 4.30 Directory for the SW component if Apache server is in use
4. Put a check mark on the Forced check box to download the complete file without any
comparison between the file already present in the stand-by bank and the new file to
be downloaded.
5. Click on the Start Download button.
6. At the end press the Activate button of the Stand-by Software Package. The NE
reboots and the supervision is lost.
The WebEML must be relaunched.
4.9.1.2.2 Active Software Package Summary tab
The Active Software Package Summary tab shows the versions of the programmable
different components of the active bank.
Note: After the activation of the Standby bank, the connection between the WebEML and
the MPT is lost.