Functional description
MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01 143
Figure 3.54 — MPT-HC V2/MPT-XP/9558HC housing (external diplexer)
3.10.3.1 — RSSI monitoring point
The RSSI is available on a connector used to manually point the antenna on the field.
The higher the voltage, the higher the RSSI and the better aligned the antenna is. The RSL
is measured using a is used a voltmeter connected to the MPT with a service kit cable.
1.Without any received signal (Tx mute on the remote MPT for example), the RSL value displayed may be
more than -100 dBm. This depends on the channelization/modulation settings.
3.10.3.2 — Waveguide flange data
Table 3.40 — RSSI
Units Measurement (with MPT-HC/HC-HQAM/XP/XP-HQAM/9558HC)
Service kit cable
(Vdc)
5 4.71 4.12 3.5 2.9 2.3 1.71 1.11 0.59 0.14
RSL (dBm) -10 -20 -30 -40 -50 -60 -70 -80 -90 -100