Figure 4.73 Refresh button
4.9.1.4.9.1.2 B) Conversions
In the conversion situations described in this section, the Navigator shows only this entry:
that is without sub-menus displayed. When the button Refresh is pressed, the messages
shown hereafter will be displayed.
Hardware type conversion: The operator saved a configuration file with a MSS-1c
10 E1. Later he replaces the MSS-1c 10 E1 with a MSS-1c 16 PDH and wants to load
this saved configuration on the new MSS-1c. As the MSS-1c hardware is different, a
conversion of the data is needed to adapt the configuration to the new MSS-1c 16E1.
This message is displayed to warn the operator:
If the operator cancels the conversion, this message is displayed, the loading and
conversion are then stopped and the data displayed in the MSS-1c screens stay
unmodified.
MAC address conversion: The operator saved a configuration file on a NE. He
wants to load this configuration on another NE, with the same type of MSS-1c. As the
MAC address of the NE (used to create cross-connections) is different, a conversion
of the data is needed to adapt the configuration to the new NE. This message is
displayed to warn the operator: