Environmental and electrical characteristics
114 MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01
Table 3.15 — MPT-HC power system: power requirements
Cable type
P/N
Coaxial Cable 1AC001100022 Coaxial Cable
1AC041350001
Cable Length 0 - 100 m 100 - 200 m 200 - 300 m 300 - 440 m 0 - 100 m 100 - 190 m
Number
of MPT
ODU
Input Voltage for
Power Unit
-38.4
(Vdc)
38.4 (Vdc) 38.4 (Vdc) 38.4 (Vdc) 38.4
(Vdc)
38.4 (Vdc)
1 MPT MPT-HC + XPIC
(MPR-e only)
47.0 W 47.0 W 47.0 W 47.0 W 47.0 W 47.0 W
Cable Losses 1.9 W 4.3 W 7.2 W 13.1 W 4.7 W 11.5 W
Power Unit 2.0 W 2.0 W 2.0 W 2.0 W 2.0 W 2.0 W
Total power
consumption
50.9 W 53.3 W 56.2 W 62.1 W 53.7 W 60.5 W
MPT-HC-HQAM +
XPIC
(MPR-e only)
40.5 W 40.5 W 40.5 W 40.5 W 40.5 W 40.5 W
Cable Losses 1.9 W 4.3 W 7.2 W 13.1 W 4.7 W 11.5 W
Power Unit 2.0 W 2.0 W 2.0 W 2.0 W 2.0 W 2.0 W
Total power
consumption
44.4 W 46.8 W 49.7 W 55.6 W 47.2 W 54.0 W
2 MPT MPT-HC + XPIC
(MPR-e only)
94.0 W 94.0 W 94.0 W 94.0 W 94.0 W 94.0 W
Cable Losses 3.8 W 8.6 W 14.4 W 26.2 W 9.4 W 23.0 W
Power Unit 4.0 W 4.0 W 4.0 W 4.0 W 4.0 W 4.0 W
Total power
consumption
101.8 W 106.6 W 112.4 W 124.2 W 107.4 W 121.0 W
MPT-HC-HQAM +
XPIC
(MPR-e only)
81.0 W 81.0 W 81.0 W 81.0 W 81.0 W 81.0 W
Cable Losses 3.8 W 8.6 W 14.4 W 26.2 W 9.4 W 23.0 W
Power Unit 4.0 W 4.0 W 4.0 W 4.0 W 4.0 W 4.0 W
Total power
consumption
88.8 W 93.6 W 99.4 W 111.2 W 94.4 W 108.0 W