252 MPR-e and MSS-1c User Manual 3DB19901EFAA Edition 01
If Auto negotiation is selected, for Speed select one or several check boxes, the same
for duplex mode
If Auto negotiation is not selected, for Speed select only one value, the same for
duplex mode.
If Auto negotiation is selected, the Flow Control can be configured.
4.9.1.4.9.2.3 C) User 2 - electrical - syncE port
To configure a SyncE electrical port like user 2, proceed the same way as for user 1. In
addition configure the Network synchronization.
•Auto, if you do not use the syncE property of the port
•SyncE IN, if you use the port as synchronization input. MSS-1c receives clock from
external equipment.
•SyncE OUT, if you use the port as a synchronization output. MSS-1c sends its clock
to external equipment.
4.9.1.4.9.2.4 D) User 3 & 4-electrical / optical port
Thanks to SFP connected into the relevant slots, these two ports can be configured in
electrical or optical mode.
Once the Port Enable Check box is selected, you can choose the type of SFP in the SFP list
(Disable or Electrical or Optical)
In the Electrical mode, the configuration is like user 1.
In the Optical mode, the Port configuration can be set to Auto negotiation or not (forced
mode). The speed is always 1000 Mbit/s.
The duplex mode is always Full Duplex.
Note: Forced mode setting is not recommended for a definitive configuration.
Autonegotiation should be chosen.
Note: this feature is authorized only if the port is set in Auto negotiation mode with speed
1000 Mbit/s and full duplex only.
Note: In optical mode, User port 4 can be used as SynchE port. It is also the case for User
port 3 only on MSS-1c 16PDH.